DVR User’s Manual
30
3.6.4 Event Full Screen
This function allows the DVR to display the alarm channel in full-screen size
when an alarm is triggered. Select <None> to disable this function; select
<Main> to display the alarm channel on Main Monitor when an alarm is
triggered; select <Call> to display the alarm channel on Call Monitor; and
select <Both> to display the alarm channel on both Main Monitor and Call
Monitor.
3.6.5 Event Duration
This item determines the duration of the buzzer and Alarm Out relay function
after an alarm is triggered. The available event duration range is from 5
seconds to 999 seconds.
3.6.6 Per Channel Config
This menu is used to configure the <Video Loss Detect>, <Motion Detect>,
<Alarm In> and <Alarm Out> settings for each channel. The menu is
displayed as below.
Channel Select
Video Loss Detect
Motion Detect
Detection Config
Alarm In
Alarm Out
Copy Event Setting
3.6.6.1 Channel Select
The item is used to select a desired channel for setting the parameters. Click
on the box next to <Channel Select> to select a channel.
3.6.6.2 Video Loss Detect
This item allows users to enable or disable Video Loss as an alarm event.
Select <On> to enable Video Loss alarm events, or <Off> to disable.
Comentarios a estos manuales