UPS Shutdown Setting
When <Power Failure Scenario> is set to <Shutdown>, this item will be
available. Users have to setup under which condition the DVR should begin to
automatically shutdown. The menu is shown as below.
Min Remaining Battery Level
Min Remaining Run Time
Delay To Activate
NOTE: The DVR will begin to shutdown when one of the first two
conditions is satisfied.
- Min Remaining Battery Level
For this item, users can decide the DVR should begin to shutdown
when the remaining battery level reaches the specific percentage. The
ranges are from 5% to 95%.
- Min Remaining Run Time
For this item, users can decide the DVR should begin to shutdown
when the remaining run time reaches the specific value. The range is
from 5 minutes to 30 minutes.
- Delay To Activate
This item allows users to set the delay time before the DVR begins to
shutdown. The ranges are from 10 seconds to 20 seconds.
UPS Info
After UPS protocol is set to <APC>, this item will be available. Users can
check UPS related information as shown below.
UPS Model
UPS Protocol
UPS Status
Remaining Battery Level
Remaining Run Time
Query Time
*****
*****
Lost Communication
77 %
93 mins
16 secs ago
- UPS Model
This item shows the model name of the UPS device.